Filter Results By:

Products

Applications

Manufacturers

Electromagnetic Field

electric and magnetic field interaction.

See Also: EMF, RF Field Strength Meters


Showing results: 61 - 75 of 103 items found.

  • Near Field Probes 30 MHz up to 3 GHz

    RF2 set - Langer EMV-Technik GmbH

    The RF2 near field probe set consists of 4 passive near field probes for measurements in the development phase of the magnetic field in the range from 30 MHz to 3 GHz on electronic assemblies. The probe heads of the RF2 set allow the step by step localization of interference sources of the RF magnetic field on assemblies. From greater distances the electromagnetic interference can be detected by RF-R 400-1 and RF-R 50-1 probes. The RF-B 3-2 and RF-U 5-2 probes with their higher resolution can more precisely detect the interference sources. Field orientation and field distribution on an electronic assembly can be detected through a trained special use of the near field probe. The near field probes are small and handy. They have a sheath current attenuation and are electrically shielded. They can be connected to a spectrum analyzer or an oscilloscope with a 50 Ω input. They do not have an internal terminating resistance.

  • 3-AXIS DIGITAL AC GAUSSMETER: 1-200 kHz

    IDR-200 - Integrity Design and Reseach Corp.

    Typical Applications include checking the frequencies and magnetic fields (BW: 1 kHz -200 kHz) produced by equipments such as computer monitors, television sets, video display terminals, induction heaters, industrial, Radar, scientific/medical equipment, walk-through/hand-held detectors and ground wave energy network; etc. For more information about VLF magnetic fields and the VLF gaussmeter , see the paper titled "Very-low-frequency electromagnetic field detector with data acquisition," IEEE Trans. Instrum. Meas.,vol. 58, no. 1, pp. 129-140, Dec. 2008. by S. Hanna.

  • EMI Site Survey

    Keystone Compliance

    An EMI site survey is an independent assessment of the potential Electromagnetic Interference (EMI) risks that might interfere with an implantable electrical device such as a pacemaker or defibrillator. The assessment should be completed by a qualified and accredited independent test lab such as Keystone Compliance and in collaboration with the employer, manufacturer of the device, patient and physician. A site survey is conducted by taking various electromagnetic measurements throughout the facility. Keystone Compliance uses a broad range of industry-accepted standards and specifications to determine which electromagnetic fields exist. Following completion of the on-site survey, Keystone Compliance provides the customers with a detailed site survey report that will help identify EMI sources and zones with the potential to interact with an implantable electrical device. This information should then be shared with the physician and employer to develop an action plan to reduce potential negative effects to the patient’s health.

  • Inductive Heater

    BD-1.01 - R&J Measurement

    The device is assigned to heat the bars to the state, which allows upsetting. The DB-1.01 heater characterizes especially high watt-hour efficiency (bigger than 98%) thanks to suitable concentration of electromagnetic field in the heating zone of inductor (the solution secured by patent). It is possible to addapt the nductive heater BD-1.01 for heating any others bars.

  • Stripline Automotive 10KHz-30MHz 50 Ohm

    STPL-30 - EMCTEST

    The GTEMCELL STPL-30 Stripline is designed to produce high electric fields over a controlled bandwidth. It is used to perform EMC measurements according to automotive and aerospace standards in order totest the immunity of automotive and aircraft equipment to radiated electromagnetic fields.The STPL-30 uses a dual-sided tapered adjustable feed design into a tunable transmission line.

  • Non-Contact Voltage Detector

    VOLTCHEK - Taurus Powertronics Systems

    The VOLTCHEK is a variable non-contact voltage detector, A proximity device which detects the presence of an alternating electric or electromagnetic field. It is used by industry professionals for live or dead voltage determination of outdoor overhead or underground at URD test points. Firstly as a proximity device to determine live or dead situations and then as a touch device to verify the source has physically reached the zero AC field. This is the only equipment capable of testing all voltage from AC 415V to 765kV from a distance, beyond arcing zone.

  • TEM Cells

    EMCTEST

    Transverse Electro Magnetic (TEM) cell or Crawford cell (named after its inventor) is used to generate accurate electromagnetic waves over a wide frequency range: DC (0 Hz) to GHz., EM waves generated in the cell propagate in transverse mode and have the same characteristics as a plane wave. It can be used to calibrate E-field broadband probes for testing radiated E-field immunity as well as for measuring radiated emission from a product with a spectrum analyzer/EMI receiver.TEM cell generates a consistent electromagnetic field for testing small RF devices such as wireless pagers, receivers, portable phones, etc.

  • Area Monitoring: Measuring Stations And Measuring Sytems

    Narda Safety Test Solutions

    In everyday life, we are surrounded by electromagnetic fields (EMF) wherever we are. They come from power lines, electricity cables, cellular radio and cordless phones and many other things, too. To protect the general public, the limit values are checked regularly and sometimes monitored continuously. Narda offers various measuring stations and systems for this purpose.

  • Test Fixture, Shielding Effectiveness

    EM-2108 | 1.5 GHz – 10 GHz - Electro-Metrics Corp.

    The EM-2108 is a standard test fixture for evaluation of the electromagnetic shielding effectiveness (SE) of planar materials. The fixture is a section of coaxial transmission line broken to allow the insertion of planar test materials. Although ASTM D4935-10 is currently limited to an upper frequency of 1.5 GHz, the EM-2108 meets and complies fully with both the impedance and SE requirements called out in ASTM test method D4935-10 up to 10 GHz. These results are shown in Figures 1 & 2. The measured data relates to the shielding effectiveness due to a plane wave (far field EM wave) from which near field values for magnetic and electric fields may be inferred.

  • Waveguide Twists

    Precision Milimeter Wave

    Waveguide twists and bent types of waveguides are used extensively in electromagnetic devices. Twist waveguides are used to change the polarity of the fields. Waveguide twist VSWR is as low. Both 45° and 90° waveguide twists are available. The 45° versions being available in both right hand and left hand twist configurations.View more Twist Waveguides

  • 4051 Series Signal/Spectrum Analyzer (3Hz to max. 67GHz)

    4051 - Saluki Technology Inc.

    4051 series signal / spectrum analyzer has good expansion capacity, and can improve the features by means of flexible configuration options and also can construct testing system or redevelop by means of the output interface of all digital and analogue signals. The analyzer is applicable for signal and equipment test of fields including aviation, aerospace, radar detection, communications, electromagnetic countermeasure, and navigation.

  • Single Axis EMF/ELF Meter (30Hz to 300Hz)

    Extech 480823 - Extech Instruments Corporation

    The Extech 480823 EMF/ELF meter allows you to measure electromagnetic field radiation levels from fans, electrical appliances, wiring, and power lines. Featuring a large 1/2 in. LCD display and a sampling time of 2.5 times per second, you can be assured of easy and accurate measurements. Readings available in both mill gauss or micro Tesla. Battery included.

  • Optical Sensors

    Bee Instruments

    Optical (Infra-Red) Proximity Switches with advanced and reliable technology for every application offer a flexible solution for automation, where other Proximity Switches can not perform. Optical Proximity Switches have distinct advantage of higher sensing distance over Inductive and Capacitive types. These can work more reliably in noisy electromagnetic field. As an Infra-red wavelength is used, it is immune to visible light interference.

  • SAFEONE® Pro Personal RF Safety Monitor

    Pro SI-1100XT - LBA Group, Inc

    SafeOne® Pro SI-1100XT is an effective and economical means to monitor the strength of electromagnetic (RF) fields from mobile phone towers, microwave ovens, radio and television installations, high frequency welders, and other common workplace RF sources between 10 and 18,000 MHz. The Personal RF Monitor is an important tool in complying with FCC, OSHA, and other safe workplace requirements.

  • Near Field Probes 30 MHz up to 3 GHz

    RF6 set - Langer EMV-Technik GmbH

    The RF6 near field probe set consists of 2 passive magnetic field probes and 2 passive E field probes for measurements in the development phase of the E-field and magnetic field in the range from 30 MHz to 3 GHz on electronic assemblies. The probe heads of the RF6 set allow a step by step localization of interference sources of the RF magnetic field and RF-E-field on an assembly. From a larger distance the electromagnetic interference is detected by RF-R 50-1 for the magnetic field and by RF-E 02 for the E-field. The RF-B 3-2 and RF-E 10 probes with their higher resolution can more presicely detect the interference sources of the magnetic field and the E-field. Field orientation and field distribution on an electronic assembly can be detected by special guidiance of the near field probe. The near field probes are small and handy. They have a sheath current attenuation and are electrically shielded. They can be connected to a spectrum analyzer or an oscilloscope with a 50 Ω input. They do not have an internal terminating resistance.

Get Help